NTD Series (5-20 CFM)
Electronic Timed Drain
The Aqua-Pure NTD series timer drain is an economical drain designed to remove condensate from a wide range of compressed air applications including air dryers, compressors, and filters. The easily adjustable electronic timer, a direct acting solenoid valve and a large discharge orifice, makes this drain the most cost-effective option for reliable condensate removal.
The NTD Series Timer Drain is easy to adjust and rated for pressures up to 230 Psig. With a test switch LED “ON/OFF” indication and fully serviceable valve, the NTD offers a long list of features and benefits not typically found in other condensate drains.
NTD Series Features
- This Electronic timer, which generates adjustable pulses, is particularly suited for automatic control of draining of an air dryer or compressor as, when energized, it can initiate operation of the solenoid valve for the time necessary for draining condensates at regular adjustable intervals
- Other applications include irrigation, air blasting, etc.
- Fits directly any solenoid valve with standardized ISO 4400 / DIN connection between coil and power connector
- Large (4 mm) Valve Orifice
- Various Connection Sizes Available
- Does Not Air Lock During Operation
- Quick to Service
- Test (Micro-Switch) Feature
- Accurate Time Cycles
- Premium Components
Standard Operating Voltage
- 110-230 VOLTS / 1 PHASE / -60 HZ
Power Connection
- DIN 43650-A
Electrical Rating
- NEMA 4 (IP65)
Max. Flow Capacity
- Any
Pressure Range
- 0-250 psi / 0-17 bar
- 0-725 psi / 0-50 bar
- 0-1500 psi / 0-103 bar
- 0-4000 psi / 0-276 bar
Medium Temperature
- 34-131° F
- 1-55° C
Ambient Temperature
- 34-131° F
- 1-55° C
Timer Cycle Range (On/Off)
- 0.5-10 sec / 0.5-45 min
Timer Cycle Indication
- Bright LED Illumination
Test Feature
- Yes
Connection
- ½” / ¼” in
Drain Rate
- 4 gpm
Dimensions
- Overall, Height: 109” mm
- Overall, Width: 46” mm
- Overall, Depth: 89” mm
Body Material
- Brass (230, 725 psig)
- Stainless (1500, 4000 psig)
- CLASS 4 (ISO 8573-1)
NTD Series Models
- Digital Display Solenoid Valve Timer
- High Pressure Series 725, 1500, 4000 psig
- Upon application of power the timer resets, enters the ON state for a period of T1, then switches off for 24 hrs. This cycle is repeated until power is removed.
NTD Series Options
Your next step toward working with NEXT Air & Gas is to contact us for a Quote. Fill out the information below and give us the appropriate information needed to get started. Be sure to fill out all the contact information and our team will reach out with any questions or concerns.
If you’d rather speak to Sales Engineering, feel free to contact us at (865) 635-8178.
Below are links to product information and brochures. Please click and download at your convenience. If you have any questions or suggestions on materials you think would be helpful, please call us at (865) 635-8178.
Operation
1.
Condensation enters through the inlet side of valve. Debris is captured inside the internal strainer.
2.
When the valve activates condensate flows through the strainer up to the orifice.
3.
Open the ball valve to clean strainer or to manually drain the tank.